ExoTec® facade panel and fixing system

What is it?

An express jointed facade system that is pre-sealed to accept a variety
of decorative finishes.

Where do you use it?

As an external wall cladding in commercial and residential applications
requiring a panelled look. ExoTec® facade panel and fixing system can
be used in a full wrap panel design and/or as a composite cladding, i.e.
used in conjunction with other cladding materials.

What are the key benefits?

     

    • Pre-sealed on all six sides means it’s more stable and durable
    • Manufactured from high-density cement reinforced with cellulose fibre
    • Strong and rigid with a smooth, dense sheet surface
    • Fast to install
    • Accepts a wide variety of applied finishes, including site-applied
      textures and factory finishes
    • Improved stability for a wide range of panel finishes
    • A panel with improved moisture resistance
    • A panel that is easier to paint.

       

Specifications

Sizes

9mm

PC Size (mm)

402200 1,800 x 900
402204 2,400 x 900
402208 3,000 x 900
402201 1,800 x 1,200
402203 2,100 x 1,200
402205 2,400 x 1,200
402207 2,700 x 1,200
402209 3,000 x 1,200

12mm

402333 2,400 x 1,200
402334 3,000 x 1,200

 

More Information

Technical Info

Accessories for ExoTec® facade panel and fixing system
Backing_strip.gif

JH Backing Strip

A weather seal at horizontal panel joints.
Selling unit:
10 per pack or each
Length: 1190mm, 2390mm and 2990mm
Facade_washer.gif

JH Facade Washer

PVC washers used for exposed fastener fixing.
Selling unit: 1000 per box
Exotec_top_hat.gif

ExoTec® Top Hat Section

Proprietary rolled metal sections 124mm wide x 35mm deep x 1.15mm
gauge thickness designed to span across the building structure to support the panels and isolate differential movement of the panels from those of the structure.
Selling unit:
45 per pack or each
Length: 6000mm
7200mm
Intermediate_top_hat.gif

Intermediate JH Top Hat

Rolled metal sections 50mm wide x 35mm deep x 1.15mm gauge thickness, designed to span across the building support structures and to be used as intermediate support to the panels.
Selling unit:
50 per pack or each
Length: 6000mm
7200mm
Gasket_snap_trip.gif

ExoTec® Gasket Snap Strip

Specially designed to clip into the JH Top Hat at vertical sheet joints to cover fixings to the structure and to provide an initial weather seal and drainage using the neoprene gasket.
Selling unit:
10 per pack or each
Length: 3620mm
Joint_sealant.gif

JH Joint Sealant

Multi purpose polyurethane based sealant used for control joints and movement joints.
Selling unit: 20 per box
300ml cartridge
*Not to be used in impact and/or fire applications.
Saw_blade.gif

HardieBlade™ Saw Blade

Ø 185mm Poly diamond blade, for fast, clean cutting of James Hardie cellulose reinforced cement.
Selling unit: each
FAQ for ExoTec® facade panel and fixing system

What is the difference between HardiPanel® Compressed Panel and ExoTec® Facade Panel?

ExoTec® Facade Panel is a new generation engineered fibre composite panel that is sealed all six sides. It has been specifically developed to meet the requirements of commercial facades, with improved stability for a greater range of paint finishes. The ExoTec® Facade Panel has 20% higher impact resistance, requires less fixings,  and is faster to paint.

Is the ExoTec® Facade Panel a type of compressed panel?

Yes

Is back coating of the ExoTec® Facade Panel required before installing as a facade?

No, ExoTec® Facade Panel is fully sealed, hence back coating is no longer required.

What happens if ExoTec® Facade Panels are scratched prior to the application of the finishing paint system?

Deep scratches through the coating will not affect the performance of ExoTec® Facade Panel. If panels are scratched through the coating, the face of the panel must be painted according to the coating specification supplied by the selected approved paint manufacturer.

What happens if ExoTec® Facade Panel edges acrylic coated are cut on/off site?

Cut unsealed edges do not affect the performance of ExoTec® Facade Panel provided that cut panel edges are painted as per instructions from the selected approved paint manufacturer.

What is the ExoTec® Facade Panel warranty?

The warranty is 10 years.

Can the back of the ExoTec® Facade Panel be exposed to UV light?

If exposed to direct UV light, then the back of the panel must be protected by either using sarking or applying a pigmented exterior grade paint to the back of ExoTec® Facade Panel.

Why is ExoTec® Facade Panel sealed six sides?

It enhances the panel’s performance by improving the panel’s moisture resistance. It removes the risk associated with an incorrect back sealing product being used.

 Can I use the ExoTec® Facade Panel in domestic type construction?

ExoTec® Façade Panel can only be used in domestic construction if the ExoTec Fixing System is used.

Can any other coating system be used other than those tested with the ExoTec® Facade Panel?A. It is the responsibility of the coating manufacturer to ensure the suitability of their coating with the ExoTec® Facade Panel.Back to top

It is the responsibility of the coating manufacturer to ensure the suitability of their coating with the ExoTec® Facade Panel.

What size drill must be used to drill holes for the No 10 countersunk or wafer head screws with the ExoTec® Facade Panel?

A 6mm masonry drill which drills a hole 6.2mm to 6.3mm diameter.

 Can ExoTec® Facade Panel be used for applications other than facades?